CPC 310.3 · General rules

No waste connections to a closet bend or stub

Don't connect any other waste to the closet bend or stub of a water closet or similar fixture.

2025 California Plumbing Code, Chapter 3 (General Regulations) · Applies to: Homes and commercial buildings

A toilet over its closet bend with a lavatory drain tying into the bend marked not allowed, and the same lavatory drain joined to the branch farther downstream marked allowed.
Other fixtures drain into the branch or stack, never into the closet bend or stub of a water closet. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

The closet bend (or stub) is the piece under the toilet that carries it into the drain. The code allows no waste connection into it.

That means a lavatory, tub, shower, laundry, or floor drain can't tie into the pipe under a toilet. Those fixtures drain into the branch or the stack with the proper fittings, each with its own trap and vent.

The rule covers similar fixtures, too, not just a water closet. If a plan or an old house shows another drain feeding the closet bend, it gets moved to the branch or stack. The inspector and the city's adopted edition of the code have the final word.

On the job

  • Check the bath group layout before rough-in. The lav and tub wastes land on the branch or stack, not on the closet bend.
  • On a remodel, look under the floor when the flange comes up. A lav, tub, or washer line tied into the bend or stub is a common surprise.
  • A bathroom floor drain doesn't tie into the closet bend either.

The inspector and your city's adopted edition have the final word.