Home › FAQ

Plumbing FAQ

Plumbing questions, answered

Does a water heater need a permit? Yes, before it goes in. Is 80 psi too much pressure? Over 80 psi, the code wants a regulator. Here are the answers to the questions we hear most, with the code section for each.

Short answers to the plumbing questions homeowners, builders and general contractors ask most. The numbers come from the 2025 California Plumbing Code (CPC), and each answer links to the code library section behind it. Your city's building department and its adopted edition of the code have the final word.

Permits and inspections

Do I need a permit to replace a water heater?

Yes. It's unlawful to install, remove or replace a water heater without first getting a permit from your local building department, and a like-for-like swap counts as a replacement. The permit is what triggers the inspections, including a final once the work is in. Don't let anyone close up a wall or enclosure around the heater or its vent before that inspection is done.

In the code library: CPC 502.1, Permit required to install, remove or replace a water heater; CPC 503.2, Final water heater inspection.

Which plumbing repairs don't need a permit?

Two small jobs are exempt: stopping leaks in drain, soil, waste or vent pipe, and clearing a stoppage or repairing a leak without replacing or rearranging valves, pipes or fixtures. Replacing a defective trap or drain pipe is new work and needs a permit. Exempt from a permit isn't exempt from the code, so if you can't tell which side your job is on, ask your building department or a licensed plumber before you start.

In the code library: CPC 104.2, Small repairs that don't need a permit.

What inspections does plumbing work get?

Three are named in the code: underground (after the trench is dug and the pipe is in and bedded, before backfill), rough-in (before wall or ceiling coverings go on) and final (when the installation is complete). The permit holder schedules each one, and the building department can add others. Water supply piping can't be covered until it's been tested, inspected and approved.

In the code library: CPC 105.2, Required inspections: underground, rough-in, final; CPC 105.3, Testing plumbing systems before approval.

What happens if plumbing work was done without a permit?

The code calls for a special investigation before a permit is issued for work that started without one, plus an investigation fee equal to the permit fee on top of the permit fee. Paying it doesn't excuse the work from the code or from other penalties. Your building department sets its own fees and process.

In the code library: CPC 104.1, Plumbing permits: one for each building or structure.

How long does a plumbing permit last in California?

California makes a permit invalid if work doesn't start within 12 months of issuance or if work is suspended or abandoned for 12 months. The building official can grant written extensions of up to 180 days each for justifiable cause. Some model-code text still prints a single 180 day extension, so ask your building department which rules it applies.

In the code library: CPC 104.4, Permit issuance, approved plans, and expiration.

Who has the final word, the code book or the inspector?

Your city or county building department, the authority having jurisdiction, enforces the edition of the code it has adopted, and its inspector's call on your job is the one that counts. Anything the code doesn't provide for goes to the building department for approval before it's installed, and tests are done in the presence of the inspector.

In the code library: CPC 301.2, Listed and marked pipe, fittings, and fixtures; CPC 105.3, Testing plumbing systems before approval.

Water heaters

How do I size a water heater?

Storage water heaters are sized by first-hour rating, the gallons a full tank can deliver in one hour, not by tank size. Table 501.1(2) goes by bathroom and bedroom count: a home with 2 to 2.5 baths and 3 bedrooms needs at least 62 gallons. The rating is on the Energy Guide label.

In the code library: CPC 501.1, Water heater sizing: first-hour rating and product standards.

Does my water heater need earthquake straps?

Yes. California requires a water heater to be anchored or strapped against sideways movement, with straps in the upper third and the lower third of the tank and the lower strap at least 4 inches above the controls. You can check yours: two metal straps, one high and one low, tied to the wall or framing. If it has none, or they look loose, call a licensed plumber.

In the code library: CPC 507.2, Earthquake strapping for water heaters (California).

Why is the pipe on my water heater dripping?

That pipe is the discharge line from the T&P relief valve, and a drip means the valve is opening for a reason. It's often high house pressure with no working expansion tank, or a worn valve. Don't cap or plug the pipe: the code allows no shutoff valve between the valve and the heater or on its discharge pipe. Call a licensed plumber to check the pressure, the tank and the valve.

In the code library: CPC 608.5, Relief valve discharge piping (T&P drain line); CPC 504.6, T&P relief valve: no shutoff valve, capacity at least the heater's input; CPC 504.4, Overpressure protection: relief setting above service pressure, 150 psi max.

Does a water heater need an expansion tank?

Yes, if the plumbing has a check valve, backflow preventer or other normally closed device that traps pressure inside the house. The code requires an approved expansion tank on the building side of that device. A pressure regulator makes the house a closed system too, so the tank goes on the cold line downstream of it. An instantaneous non-storage heater doesn't need one.

In the code library: CPC 608.3, Expansion tanks and combination T&P valves; CPC 608.2, Pressure regulator when street pressure is over 80 psi.

When does a water heater need a drain pan?

When it sits in an attic, over a floor-ceiling or floor-subfloor assembly, or anywhere a leak would cause damage. The pan has to be watertight and corrosion-resistant, at least 1-1/2 inches deep, with a drain of at least 3/4 inch that runs to a visible termination.

In the code library: CPC 507.5, Water heater drain pan (attics, upper floors and where leaks do damage).

Can a water heater go in a garage, bedroom or bathroom?

In a residential garage, the burners, switches and ignition parts have to sit at least 18 inches above the floor unless the heater is a listed FVIR model, and it has to be protected from vehicle damage. In a bedroom or bathroom it has to be direct-vent, or a fuel-burning heater has to sit in a closet with a listed gasketed self-closing door, outdoor combustion air and nothing else in it.

In the code library: CPC 507.13, Water heaters in residential garages: 18 inches off the floor; CPC 504.1, Water heaters in bedrooms and bathrooms.

Water pressure and supply

How much water pressure is too much for a house?

Static pressure over 80 psi. At that point the code requires an approved pressure regulator, with a strainer ahead of it, that brings the building down to 80 psi or less. An expansion tank then goes on the cold side downstream of the regulator. You can read your own pressure with an inexpensive gauge that threads onto an outside hose bibb, with nothing else running. A steady reading over 80 psi is worth a call to a licensed plumber. Don't adjust the regulator yourself.

In the code library: CPC 608.2, Pressure regulator when street pressure is over 80 psi.

What's the minimum water pressure a house should have?

The code wants at least 15 psi of residual pressure at the fixtures, measured while water is flowing and after friction and other losses. If the supply can't deliver it, a tank and pump or another means has to. If one shower or an upstairs sink runs weak, a licensed plumber can measure with the water running and tell you whether it's the supply, the piping or a clogged fixture.

In the code library: CPC 608.1, Minimum 15 psi residual pressure at the fixtures.

How hot can the water be at a shower or tub?

The water at a showerhead is limited to 120°F (49°C), set by adjusting the shower valve or its limit stop, and every shower or tub-shower needs its own pressure-balance, thermostatic or combination valve. Hot water from a tub or whirlpool filler is also capped at 120°F, by a limiting device or a conforming water heater.

In the code library: CPC 408.4, Shower valves: pressure balance or thermostatic, 120°F limit; CPC 409.4, 120 degree limit on tub and whirlpool filler water.

What water-use limits apply to faucets, showerheads and toilets?

A residential lavatory faucet is capped at 1.2 gpm at 60 psi, a showerhead at 1.8 gpm at 80 psi and a toilet at 1.28 gallons per flush. Where state appliance law sets a lower rate, the lower rate applies. Nonresidential limits come from CALGreen.

In the code library: CPC 407.2, Faucet flow limits: lavatory and metering faucets; CPC 408.3, Showerhead and body spray flow limits; CPC 411.2, Toilet flush volume: 1.28 gallons per flush; CPC 401.3, Water-conserving fixtures: where California's flow limits live.

Drains and sewers

How much slope does a drain need?

At least 1/4 inch per foot (2 percent), at a uniform grade toward the point of disposal. A building drain of 4 inches or larger can go down to 1/8 inch per foot (1 percent) only if the authority having jurisdiction approves it first. A slow drain on the lowest level or gurgling upstairs can mean a belly or a stoppage, which is a job for a licensed plumber with a camera, not chemicals.

In the code library: CPC 708.1, Slope of building drain and horizontal drains.

Where does the code require cleanouts?

A horizontal drain needs a cleanout at its upper end and another for each 100 feet of run, plus one for each aggregate horizontal change of direction over 135 degrees. Each has to be readily accessible with clear space in front: 18 by 18 inches on pipe 2 inches or smaller and 24 by 24 inches on larger pipe. Know where yours are and keep them uncovered.

In the code library: CPC 707.0, Where drain cleanouts are required (Section 707.4); CPC 707.8, Cleanout access and clearances.

Do I need a backwater valve?

If a fixture sits on a floor lower than the next upstream manhole cover of the sewer, yes: it has to be protected by an approved backwater valve. Fixtures on higher floors can't drain through the valve. Think basement bath, lower-level laundry or a floor drain below street level, and ask a licensed plumber whether the manhole elevation calls for one.

In the code library: CPC 710.1, Backwater valve for fixtures below the sewer manhole.

Does my building have to connect to the public sewer?

Yes where one's available. A building with plumbing fixtures has to connect to a public or private sewer, and a public sewer can be treated as unavailable only where it's more than 200 feet from the proposed building. California adds that the authority having jurisdiction may consider the sewer unavailable for residential occupancies. Ask your city or sewer district early.

In the code library: CPC 713.1, When a building has to connect to a sewer.

What's the difference between the building drain and the building sewer?

The building drain is the lowest horizontal piping inside the building that gathers all the drainage, and it ends 2 feet outside the building wall. The building sewer starts there and carries the discharge to the public sewer, a private sewer or another approved point of disposal. The sewer has its own sizing, slope and cleanout rules, and it can't be smaller than the building drain.

In the code library: CPC 717.1, Building sewer size; CPC 718.1, Building sewer slope; CPC 719.1, Building sewer cleanouts.

Why does every fixture need a trap and a vent?

The trap holds a water seal, 2 to 4 inches deep, that keeps sewer gas out, and the vent lets air in so the seal isn't siphoned out. The trap can't be farther from its vent than Table 1002.2 allows: for a 1-1/2 inch trap arm that's 42 inches, and for a 2 inch arm it's 60 inches. S-traps, bell traps and crown-vented traps are prohibited.

In the code library: CPC 1005.1, Trap seal depth: 2 to 4 inches; CPC 1002.2, How far a trap can be from its vent (trap arm length); CPC 1004.1, Prohibited traps: S-traps, bell traps, crown-vented traps; CPC 901.2, Every fixture trap needs a vent.

Why does my floor drain smell?

A trap that isn't used dries out, and a dry trap lets sewer gas into the building. The code requires a trap seal primer on an infrequently used floor drain unless the authority having jurisdiction waives it, and the primer has to be accessible. If the smell keeps coming back, ask a licensed plumber about a primer.

In the code library: CPC 1007.1, Trap seal primers for infrequently used floor drains.

Gas

What should I do if I smell gas?

Leave the building, then call the gas utility or 911 from outside. Don't try to find the leak, turn valves or fix anything yourself. Gas piping is work for a licensed plumber and an inspector.

In the code library: CPC 1210.9, Manual gas shutoff valves.

Does gas piping work need a permit and an inspection?

Yes. Gas piping gets a rough inspection after it's installed and before anything covers it or an appliance is hooked up, then a final inspection once the concealed parts are closed in. The pressure test happens at the final, and a certificate of inspection can be issued after it. Gas piping isn't a DIY job.

In the code library: CPC 1203.3, Rough and final gas piping inspections; CPC 1213.3, Gas piping pressure test.

What pipe can carry natural gas?

Steel, stainless steel and wrought-iron gas pipe has to be at least Schedule 40. Tubing, listed CSST and ASTM D2513 polyethylene are allowed in their places. Cast iron, PVC and CPVC can't carry fuel gas.

In the code library: CPC 1208.5, Gas piping materials: what's allowed and what isn't.

Does CSST gas pipe need to be bonded?

Yes. CSST, or any gas system with a CSST segment in it, has to be electrically continuous and bonded to the electrical service grounding electrode system. The bonding jumper is at least 6 AWG copper and the run can't exceed 75 feet. If you see a clamped wire on your gas piping near the meter or water heater, leave it in place.

In the code library: CPC 1211.2, Bonding CSST gas piping; CPC 1210.2, CSST gas piping basics.

Where does the gas shutoff valve go, and what's the capped pipe below it?

Every gas appliance needs its own accessible manual shutoff valve within 6 feet of it. Downstream of that valve, close to the appliance, is usually a sediment trap: a tee with a capped nipple in the bottom outlet. Leave the cap alone. Ranges, dryers and gas fireplaces don't need one.

In the code library: CPC 1212.6, Appliance shutoff valve within 6 feet; CPC 1212.9, Sediment trap at the appliance.

Do I need an earthquake gas shutoff valve?

The CPC requires one only where a local ordinance does. If one is installed, it has to be certified by the State Architect. Ask your city or county building department whether an ordinance applies to your property.

In the code library: CPC 1211.8, Earthquake-actuated gas shutoff valves.

Backflow and irrigation

Why does my sprinkler system need a backflow preventer?

So used or dirty water can't flow backward into the drinking water. With no pump and no chemical injection, an AVB, PVB, SVB, RP assembly or an IAPMO PS 72 valve can protect it. With a pump, or backpressure from downstream, or chemical injection such as a fertilizer injector, it takes an RP assembly.

In the code library: CPC 603.5.6, Lawn sprinklers and irrigation backflow protection.

How often does a backflow assembly need testing?

At installation, repair or relocation, and then at least once a year, by a certified backflow assembly tester or repairer, or more often if the authority having jurisdiction requires. Check the date on the test tag. Don't test or adjust the assembly yourself.

In the code library: CPC 603.2, Backflow devices: approval, annual testing and who can test them.

What's the difference between an AVB, a PVB, a DC and an RP?

An AVB and a PVB protect against back-siphonage only. An AVB goes at least 6 inches above the downstream piping and flood-level rim, and a PVB, which adds test cocks and shutoff valves, goes at least 12 inches above. A double check assembly (DC) covers backpressure too but only at the low hazard level. An RP assembly covers both directions at both hazard levels.

In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP).

Do outdoor hose faucets need a vacuum breaker?

Yes. A hose bibb needs a nonremovable backflow preventer or vacuum breaker, or an atmospheric vacuum breaker at least 6 inches above the highest point of use, on the discharge side of the last valve. Don't remove the small cap or vent on the spout, and don't leave hoses lying in a pool or bucket.

In the code library: CPC 603.5.7, Hose bibbs and outlets with hose threads.

What's the cap next to my kitchen faucet?

That's usually the dishwasher air gap fitting. A residential dishwasher can't drain directly into the drainage system or a food waste disposer, so it goes through an approved air gap fitting with its flood-level mark at or above the flood level of the sink or drainboard, whichever is higher. You can lift the cap and clear debris with a brush. If it sprays when the dishwasher drains, call a licensed plumber.

In the code library: CPC 807.3, Domestic dishwasher air gap fitting; CPC 414.3, Dishwasher drain: air gap fitting connections.

Can I send laundry water to my yard without a permit?

A clothes washer gray water system can go in without a construction permit if there's no potable water connection and no added pump, a labeled valve lets you send the flow to the landscape or the sewer, nothing ponds or runs off, and any release above ground has at least 2 inches of cover. Anything bigger takes a permit. Call your building department and a licensed plumber.

In the code library: CPC 1503.1.1, Clothes washer gray water system (laundry to landscape) without a permit; CPC 1503.1, Gray water systems: the general rules and permit tiers.

Remodels and new construction

Do I have to bring all my plumbing up to code in a remodel?

No. New work in an addition, alteration, renovation or repair has to meet the code for a new system, but the rest of the existing plumbing doesn't have to be upgraded, as long as the new work doesn't leave it unsafe, insanitary or overloaded. Plumbing that was lawful when installed can stay in use and be maintained as originally designed, as long as it isn't a hazard.

In the code library: CPC 102.4, Additions, remodels, and repairs: new work meets code; CPC 102.2, Existing plumbing that was legal when it went in.

How much room does a toilet need?

At least 15 inches from the center of the toilet to a side wall or obstruction, at least 30 inches center to center from a similar fixture, and at least 24 inches of clear space in front. A lavatory or bidet gets the same 24 inches in front.

In the code library: CPC 402.5, Toilet, bidet and urinal clearances.

How big does a shower have to be?

The finished interior has to be at least 1024 square inches and able to fit a 30 inch circle, held up to 70 inches above the drain outlet. A receptor at least 30 inches wide and 60 inches long is exempt from the area and circle test. A site-built receptor is tested with water at least 2 inches deep for at least 15 minutes.

In the code library: CPC 408.7, Shower compartment minimum size; CPC 408.8, Site-built shower pan lining and the 2 inch water test.

How is new plumbing tested?

A drain and vent water test fills the system with at least a 10 foot head of water held for at least 15 minutes. An air test holds a uniform 5 psi for at least 15 minutes, and plastic pipe can't be air tested. Water supply piping is tested with water at working pressure or higher, or air at 50 psi or more, with no leakage for at least 15 minutes. Tests are done in the presence of the inspector.

In the code library: CPC 712.2, Water test for drain and vent piping; CPC 712.3, Air test for drain and vent piping; CPC 609.4, Testing water piping: water or 50 psi air for 15 minutes; CPC 105.3, Testing plumbing systems before approval.

Does new PEX plumbing get flushed before move-in?

In California housing, PEX that's the first plumbing installed in new construction gets flushed for at least 10 minutes, filled and left standing at least 1 week, then every branch is flushed again. Each fixture gets a removable tag at the fill. If you move in less than a week after the fill date on the tag, run each tap for at least 2 minutes before drinking from it.

In the code library: CPC 604.1.2, New PEX: flush, wait a week, flush again, tag the fixtures.

Does a detached garage or ADU share the house's plumbing permit?

No. Plumbing permits go by building or structure, so a main house and a detached garage or detached ADU each get their own. Each new building also gets its own drain and sewer connection where a sewer is available, with one exception for a rear building on an interior lot with no sewer available to it.

In the code library: CPC 104.1, Plumbing permits: one for each building or structure; CPC 311.1, Each building gets its own drain and sewer connection.

Working with Hoffman & Sons Plumbing

Is Hoffman & Sons Plumbing licensed?

Yes. Hoffman & Sons Plumbing is a Licensed C-36 Plumbing Contractor, CSLB license #1154157. You can look it up on the Contractors State License Board website.

What areas do you serve?

North County San Diego and South Orange County. That covers Oceanside, Carlsbad, Vista, San Marcos, Escondido, Encinitas, Solana Beach, Del Mar, Rancho Santa Fe, Fallbrook, Bonsall, Valley Center, Poway and Ramona in North County, and San Clemente, Dana Point, San Juan Capistrano, Ladera Ranch, Rancho Mission Viejo, Mission Viejo, Laguna Niguel and Rancho Santa Margarita in South Orange County. Outside these areas, call anyway: we travel for the right job. See the service area page.

Who do you work with?

Homeowners, builders and general contractors, on residential and commercial work. That includes new construction, remodels and additions, and service and repair.

What does your new construction plumbing include?

Complete plumbing system installation, underground and slab plumbing, water and sewer lines, rough-in plumbing, drain, waste and vent systems, gas line installation, water heater installation, fixture installation and connections, final plumbing and trim-out, and code compliance and inspections. Details are on the new construction page.

What does your service and repair work cover?

Water heater installation and replacement, faucet repair and replacement, toilet repair and replacement, sink and fixture installation, garbage disposal service, leak detection and plumbing repairs, drain and sewer issues, water line repairs, repiping, shut-off valve replacement, gas line repairs and general plumbing repairs. Details are on the service and repair page.

How much experience do you have?

30 years of plumbing knowledge, from the ground up.

How do I get a quote or reach you?

Call or text (760) 912-9831 and tell us about the job.

Give us a call

Call (760) 912-9831