Plumbing glossary

Plumbing terms, explained

Short definitions of the plumbing terms you'll hear from an inspector, a plumber or a set of plans, from air gap to yoke vent, each linked to the California Plumbing Code section behind it.

These definitions are written in our own words for homeowners, builders and general contractors, based on the 2025 California Plumbing Code (CPC). Terms the code defines in Chapter 2 say so, and each entry links to the code library section where the rule shows up on a real job. Your city's building department and its adopted edition of the code have the final word.

A

Accessible and readily accessible

Accessible means you can get to it, though you might have to take off a panel or door first. Readily accessible means you can reach it directly with nothing in the way. The code asks for one or the other at things like cleanouts, shutoff valves and backflow assemblies.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 707.8, Cleanout access and clearances; CPC 603.4.3, Access and clearance for backflow assemblies (12 inches, platform above 5 feet).

AHJ (authority having jurisdiction)

The agency or official that enforces the plumbing code where the building sits and decides on permits, inspections and approvals. For most homes that's the city or county building department. Its adopted edition of the code and its inspector have the final word.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 104.1, Plumbing permits: one for each building or structure; CPC 105.2, Required inspections: underground, rough-in, final.

Air break

A physical separation in an indirect waste connection, usually the pipe ending low inside the receptor with open air around it. It isn't measured up to the receptor's rim the way an air gap is, and where the code calls for a drainage air gap, an air break doesn't take its place.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 801.2, Indirect waste: air gap or air break, and the 1 inch drainage air gap.

Air gap

Open air between the end of a pipe and the flood-level rim of whatever it empties into. On a waste line, where the code requires a drainage air gap, it's at least 1 inch. On a supply line over a drain, it's two diameters of the supply pipe and never under 1 inch. It's the most dependable backflow barrier because nothing mechanical has to work.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 801.2, Indirect waste: air gap or air break, and the 1 inch drainage air gap; CPC 603.4.4, Potable water to a drain: air gap of two pipe diameters, 1 inch minimum.

Alternate water source

Any nonpotable water a building uses on purpose, such as gray water, rainwater, on-site treated water or recycled water. It stays out of the drinking water system, and its pipe gets its own color and marking so nobody mistakes it for potable.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 601.3, Pipe identification: potable, nonpotable and alternate water; CPC 1502.3, Cross-connection test before a nonpotable water system goes live.

AVB (atmospheric vacuum breaker)

A simple backflow device, a body with a check member and an air port, that opens to the air when supply pressure drops. It guards against back-siphonage only. It goes upright, open to the air, at least 6 inches above the downstream piping and the flood-level rim.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP); CPC 603.5.7, Hose bibbs and outlets with hose threads.

B

Backflow

Water or other liquid flowing the wrong way into the drinking water pipes from somewhere other than its intended source. It happens two ways: back-siphonage and backpressure.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 602.2, Never connect drinking water to any other water or chemical piping; CPC 603.1, Cross-connection control: water-operated equipment and treatment chemicals.

Backpressure

Backflow caused by pressure on the downstream side (a pump, a boiler, an elevated tank) climbing above the supply pressure and pushing water back into the supply pipe. A double check assembly or an RP assembly is what covers it.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP); CPC 603.5.10, Boilers and hydronic heating systems: backflow protection.

Back-siphonage

Backflow caused by pressure in the supply pipe dropping below atmospheric, which pulls used or dirty water backward from a fixture or vessel into the supply. Air gaps, AVBs and PVBs all protect against it.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP).

Backwater valve

A valve in a drain line that closes to stop sewage from flowing backward into the building. The code requires one on fixtures sitting lower than the next upstream manhole cover of the sewer, and it has to stay accessible for inspection and repair.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 710.1, Backwater valve for fixtures below the sewer manhole; CPC 710.6, Backwater valve construction and access.

Bathroom group

The set of fixtures that make up one bathroom: no more than one toilet, two lavatories, one tub or tub-shower and one shower, and it can include a bidet and an emergency floor drain. It matters because the code lets a whole group be vented together in some layouts.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 908.2, Horizontal wet vent for a bathroom group.

Building drain

The lowest horizontal piping inside the building that collects everything from the soil, waste and other drainage pipes and carries it out. It ends 2 feet outside the building wall, where the building sewer begins.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 708.1, Slope of building drain and horizontal drains; CPC 707.0, Where drain cleanouts are required (Section 707.4).

Building sewer

The piping that picks up where the building drain ends and carries the building's drainage to the public sewer, a private sewer or another approved point of disposal. It's sized by the fixture units it carries and can't be smaller than the building drain.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 717.1, Building sewer size; CPC 718.1, Building sewer slope; CPC 719.1, Building sewer cleanouts.

C

Circuit vent

One vent that serves a whole row of fixtures on a horizontal drain branch, connecting between the two most upstream trap arms. The code allows up to eight floor-outlet toilets, showers, tubs or floor drains on one circuit-vented branch, with a relief vent where needed.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 911.1, Circuit vent: up to eight fixtures on one branch.

Cleanout

An access point on a drain line, usually a capped fitting, where a plumber can clear a stoppage or run a camera. The code requires one at the upper end of each horizontal drain and at set intervals and turns after that, and each has to stay readily accessible with working space in front of it.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 707.0, Where drain cleanouts are required (Section 707.4); CPC 707.8, Cleanout access and clearances; CPC 719.1, Building sewer cleanouts.

Combination waste and vent

A specially designed drain that doubles as its own vent: oversized waste piping with air space above the flow. It's allowed only where the structure keeps you from venting conventionally, and the plans have to be approved before any of it goes in.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 910.3, Combination waste and vent: vent size and the 15 foot branch; CPC 910.4, Combination waste and vent: pipe two sizes up.

Combustion air

The air a fuel-burning appliance such as a gas water heater needs to burn cleanly. A closet or small room has to supply it with enough room volume or with permanent openings to the outdoors or to other indoor spaces.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 506.2, Indoor combustion air: how much room volume you need; CPC 506.4, Outdoor combustion air: two openings or one.

Condensate drain

The pipe that carries the water an air conditioner coil or a condensing appliance produces to an approved place. It connects to the drainage system indirectly, and the equipment needs overflow protection where a backup could cause damage.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 814.1, Condensate disposal: slope, material and where it can go; CPC 814.2, Condensate overflow protection: float switch, second pan or second drain.

Critical level (C-L)

The mark on a vacuum breaker or backflow device that tells you the lowest height it can be installed above the flood-level rim of what it serves. With no mark, the bottom of the device counts as the critical level.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 603.5.7, Hose bibbs and outlets with hose threads.

Cross-connection

Any real or possible link between the drinking water supply and something that could contaminate it: a fixture, tank, piece of equipment or another pipe system. The code requires an approved backflow device matched to the hazard wherever a cross-connection could exist.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 602.2, Never connect drinking water to any other water or chemical piping; CPC 602.3, No fixture or equipment may be able to pollute the water supply.

CSST (corrugated stainless steel tubing)

Flexible, listed stainless tubing used for fuel gas. It's installed with the maker's fittings and routing rules, and the code requires the system to be electrically continuous and bonded to the electrical service grounding electrode system.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1210.2, CSST gas piping basics; CPC 1211.2, Bonding CSST gas piping.

D

Developed length

The length of a pipe measured along its centerline, including the fittings, not in a straight line. Trap arm limits and vent lengths are all measured this way.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1002.2, How far a trap can be from its vent (trap arm length).

Direct-vent appliance

An appliance sealed so that all of its combustion air comes from outdoors and all of its flue gases go outdoors. It's one of the two ways the code lets a water heater sit in a bedroom or bathroom.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 504.1, Water heaters in bedrooms and bathrooms.

Double check assembly (DC)

A backflow assembly with two independently acting loaded check valves, test cocks and shutoff valves. It handles back-siphonage and backpressure, but only at the low hazard level, which is why high hazards get an RP assembly instead.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP).

Drainage fixture unit (DFU)

See fixture unit. DFU is the usual shorthand on plans and in Table 702.1, where each fixture and trap size gets a number you add up to size the drain.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 702.1, Drainage fixture units (DFU) and trap size; CPC 703.2, How many fixture units a drain pipe can carry.

Dry vent

A vent that never carries any waste. It's the opposite of a wet vent, and it's what a horizontally wet-vented bathroom group uses for its shower, tub or bidet.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 908.2, Horizontal wet vent for a bathroom group.

DWV (drain, waste and vent)

The part of a plumbing system that carries used water and sewage out of the building and lets air in behind it so it drains: drain, waste and vent pipe, plus the fittings and traps that go with them. DWV pipe materials and where each can be used are listed by the code.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 701.2, Drain, waste and vent pipe materials; CPC 901.2, Every fixture trap needs a vent.

E

Earthquake-actuated gas shutoff valve

A valve that closes the gas automatically when it senses strong shaking. The CPC requires one only where a local ordinance does, and an installed valve has to be certified by the State Architect.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1211.8, Earthquake-actuated gas shutoff valves.

Expansion tank

A small pressurized vessel on the cold water line that absorbs the swelling of water as it heats. It's needed whenever a check valve, backflow preventer or regulator traps the pressure inside the house, and it goes on the building side of that device.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 608.3, Expansion tanks and combination T&P valves; CPC 608.2, Pressure regulator when street pressure is over 80 psi.

F

Firestop

A tested product or assembly that restores a fire rating where a pipe passes through a fire-rated wall or floor. Combustible pipe such as PVC, ABS or PEX through a rated assembly needs a tested penetration firestop system.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1404.3, Firestop systems for plastic pipe through rated walls and floors; CPC 1405.2, Metal pipe through concrete: grout instead of a firestop product.

Fixture unit (DFU)

A load number the code assigns to each kind of fixture to express how hard it hits the drain, on a scale chosen for convenience, not a measure of gallons. You add the units up to size drains, vents and sewers. In a home, a lavatory is 1 DFU, a bathtub is 2 and a 1.6 gpf water closet is 3.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 702.1, Drainage fixture units (DFU) and trap size; CPC 703.2, How many fixture units a drain pipe can carry.

Flood-level rim

The top edge of a fixture or receptor, the level where water would spill over. Air gaps, vent heights and dishwasher air gap fittings are all measured from it.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 905.3, Vent rise: 6 inches above the flood-level rim before offsetting; CPC 807.3, Domestic dishwasher air gap fitting.

Floor drain

A drain in a floor that counts as a plumbing fixture in the code. It needs a strainer, a trap that can be cleaned, and its inlet in full view, and where sewage could back up, a backwater valve.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 418.2, Floor drains: strainer and where they're required; CPC 1006.1, Floor drains: cleanable trap and drain inlet in full view.

Fullway valve

A shutoff valve, usually a ball or gate valve, that doesn't restrict flow when it's open. The code calls for one on the discharge side of the water meter, at each building, at supply tanks and on the cold supply to water heaters.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 606.2, Fullway shutoff valves: meter, each building, tanks, water heaters.

FVIR water heater

A water heater listed to resist igniting flammable vapors, short for flammable vapor ignition resistant. It matters in garages, where a heater without that listing has to have its burner and ignition parts at least 18 inches off the floor.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 507.13, Water heaters in residential garages: 18 inches off the floor.

G

Gas appliance shutoff valve

The manual valve at each gas appliance. The code wants each appliance to have its own accessible, approved shutoff within 6 feet of it, upstream of any connector. It's separate from the building's exterior emergency shutoff.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1212.6, Appliance shutoff valve within 6 feet; CPC 1210.9, Manual gas shutoff valves.

Grade (slope)

How much a pipe falls toward its outlet, usually written as inches of drop per foot of run. Building drains and horizontal drains need at least 1/4 inch per foot.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 708.1, Slope of building drain and horizontal drains; CPC 718.1, Building sewer slope.

Gray water

Used water from fixtures such as showers, lavatories and clothes washers that's collected and reused for irrigation instead of going to the sewer. A gray water system needs a labeled diverter valve and can't pond, run off or spray.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1503.1, Gray water systems: the general rules and permit tiers; CPC 1503.1.1, Clothes washer gray water system (laundry to landscape) without a permit.

Grease interceptor

A device in the drain of a commercial kitchen that catches fats, oils and grease before they reach the building drain and the sewer. Toilets and urinals never drain through one, and it has to be cleaned regularly.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1014.1, Grease interceptors: where they go and what can't connect; CPC 1014.2, Hydromechanical grease interceptors: flow control, vent, and capacity.

H

Hose bibb

An outdoor faucet with a hose thread. It needs a backflow preventer or vacuum breaker, either built in and nonremovable or an AVB placed at least 6 inches above the highest point the hose can reach.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 603.5.7, Hose bibbs and outlets with hose threads.

Hot water

In the code, water at 120°F (49°C) or hotter. It's also the number behind the limit on hot water delivered to showers, tubs and public lavatories.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 408.4, Shower valves: pressure balance or thermostatic, 120°F limit; CPC 407.3, 120 degree limit on public lavatory hot water.

I

Indirect waste

A drain that doesn't connect straight to the sewer side. It empties through an air gap or air break into a trapped receptor, such as a floor sink or standpipe, that is itself connected to the drainage system. Food equipment, ice machines and condensate lines are typical examples.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 801.2, Indirect waste: air gap or air break, and the 1 inch drainage air gap; CPC 803.3, Indirect waste pipe size, length, traps and vents.

Individual vent

A vent pipe serving a single fixture trap. It connects to the vent system above that fixture or ends in the open air.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 901.2, Every fixture trap needs a vent; CPC 904.1, Vent size: 1-1/4 inch minimum and half the drain.

Interceptor

A device that separates and holds back unwanted matter, such as grease, oil or sand, so normal wastewater can flow on to the sewer. Restaurant kitchens use grease interceptors, and repair garages and gas stations use oil interceptors.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1014.1, Grease interceptors: where they go and what can't connect; CPC 1017.1, Oil interceptors for repair garages and gas stations.

L

Leader

The exterior vertical pipe that carries storm water down from a roof or gutter drain. Leaders carry only storm water, and they're sized from the roof area they serve.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1101.16, Leaders: no mixing with waste or vent, and protect them from damage; CPC 1103.1, Sizing leaders and vertical conductors (Table 1103.1).

Listed

Included in a list published by a testing or listing agency that keeps checking the product being made, and certifying it meets approved standards. Most pipe, fittings, fixtures and devices have to be listed for the code to accept them.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 301.2, Listed and marked pipe, fittings, and fixtures.

M

Manifold (home-run water piping)

A fitting that feeds several water lines out to individual fixtures, the heart of a parallel or home-run system. The code wants a control valve at each fixture or at the manifold, labeled for the fixture, with extra conditions if the manifold is in an attic, crawl space or similar space.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 606.5, Control valves at appliances, fixtures and manifolds.

N

Nonpotable water

Water that isn't safe to drink. Where a building has both, the code marks potable pipe green with white lettering, nonpotable pipe yellow with black lettering that warns against drinking it, and alternate-source pipe purple.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 601.3, Pipe identification: potable, nonpotable and alternate water; CPC 1505.5, Recycled water: 15 psi at the far outlet, 80 psi cap, purple pipe and marking.

P

Potable water

Water that's satisfactory for drinking, cooking and household use and meets the requirements of the health authority. Pipe, fittings, solder and flux in a potable system have to meet NSF/ANSI/CAN 61, and lead content is capped.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 604.1, Approved materials for drinking water piping; CPC 604.2, Lead limits in drinking water pipe, fittings and fixtures.

Pressure-balance and thermostatic valves

Two kinds of shower valve. A pressure-balancing valve compensates when hot or cold pressure changes, and a thermostatic valve senses outlet temperature and compensates for swings in either supply. Every shower and tub-shower needs one, and it limits the water at the showerhead to 120°F.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 408.4, Shower valves: pressure balance or thermostatic, 120°F limit.

Pressure regulator (PRV)

A valve that knocks high supply pressure down to a safe level for the building. When static pressure is over 80 psi, the code requires an approved regulator with a strainer ahead of it, set to bring the building to 80 psi or less. The expansion tank goes on the cold side after it.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 608.2, Pressure regulator when street pressure is over 80 psi.

Pressure test

A test where a section or the whole system is filled with water or air and watched to see that it holds, in front of the inspector. Drain and vent systems, water supply, gas and storm piping each have their own test rules.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 712.2, Water test for drain and vent piping; CPC 712.3, Air test for drain and vent piping; CPC 609.4, Testing water piping: water or 50 psi air for 15 minutes.

PVB (pressure vacuum breaker)

A backflow assembly with a loaded air inlet valve, a loaded check valve, two test cocks and two shutoff valves. It protects against back-siphonage only, and it goes upright at least 12 inches above the downstream piping and the flood-level rim.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP); CPC 603.5.6, Lawn sprinklers and irrigation backflow protection.

R

Receptor

The approved fixture or device that receives the discharge of an indirect waste pipe. It has to be shaped and located so it's readily cleaned, and a clothes washer standpipe is one of the common ones.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 804.1, Clothes washer standpipe: 18 to 30 inches above the trap weir; CPC 801.2, Indirect waste: air gap or air break, and the 1 inch drainage air gap.

Recycled water

Highly treated wastewater from a utility that meets California's statewide criteria for nonpotable reuse. Where a building is plumbed for both, it can serve toilets, urinals, trap primers and irrigation, and its pipe is purple and marked.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1505.1, Recycled water in buildings: where it applies and what it can be used for; CPC 1505.5, Recycled water: 15 psi at the far outlet, 80 psi cap, purple pipe and marking.

Relief vent

A vent whose main job is to move air between the drainage and vent systems, or to act as an auxiliary vent on a specially designed system. A circuit-vented branch uses one where the code requires it.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 911.1, Circuit vent: up to eight fixtures on one branch.

Residual pressure

The pressure left at a fixture while water is flowing, after pipe friction, the meter, fittings and elevation take their share. The code wants at least 15 psi there.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 608.1, Minimum 15 psi residual pressure at the fixtures.

Rough-in

The stage where drain, vent and supply piping is installed in the framing before walls and ceilings are closed. The rough-in inspection happens before any wall or ceiling covering goes on.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 105.2, Required inspections: underground, rough-in, final.

RP assembly (reduced-pressure principle)

The strongest backflow assembly: two independently acting loaded check valves, a differential pressure relief valve, four test cocks and two shutoff valves. It covers back-siphonage and backpressure at both low and high hazard levels, so it's the choice for high hazards and for irrigation with pumps or chemical injection.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 603.3, Which backflow device protects against what (air gap, AVB, PVB, DC, RP); CPC 603.5.6, Lawn sprinklers and irrigation backflow protection.

S

Sanitary tee

A tee fitting with a curved inlet, allowed where a horizontal drain enters a vertical stack. It isn't on the code's list for joining two horizontal drains.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 706.2, Horizontal drain entering a vertical stack; CPC 706.3, Horizontal drain joining another horizontal drain.

Sediment trap

A short drop in the gas line just before an appliance that catches dirt and moisture before it reaches the burner controls. It's a tee with a capped nipple in the bottom outlet, set downstream of the appliance shutoff valve unless the appliance has one built in.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1212.9, Sediment trap at the appliance.

Stack vent

The extension of a soil or waste stack up through the roof, above the highest horizontal drain that connects to the stack. It ends in the open air above the roof.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 906.1, Roof vent: 6 inches above the roof, 1 foot from walls.

Static pressure

The water pressure in a pipe with no water flowing. It's the number that decides whether a house needs a pressure regulator.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 608.2, Pressure regulator when street pressure is over 80 psi.

T

T&P valve

The combination temperature and pressure relief valve on a storage water heater. It opens if the water gets too hot or the pressure too high. It never gets a shutoff valve, and its discharge pipe has to be full size, unvalved and untrapped.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 504.6, T&P relief valve: no shutoff valve, capacity at least the heater's input; CPC 608.5, Relief valve discharge piping (T&P drain line); CPC 608.3, Expansion tanks and combination T&P valves.

Trap

A fitting or bend that holds a water seal in the drain to keep sewer gas out of the building. Every fixture needs its own approved trap, and S-traps, bell traps and crown-vented traps are prohibited.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1001.2, Every fixture gets its own trap; CPC 1004.1, Prohibited traps: S-traps, bell traps, crown-vented traps.

Trap arm

The part of the fixture drain between the trap and the vent. Its developed length has to stay within the limits in Table 1002.2 so the vent can protect the trap seal.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 1002.2, How far a trap can be from its vent (trap arm length).

Trap primer

A device that puts a little water into a floor drain trap on a regular basis so the seal doesn't dry out. Infrequently used floor drains need one unless the authority having jurisdiction waives it.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1007.1, Trap seal primers for infrequently used floor drains.

Trap seal

The water held in a trap that blocks sewer gas. The seal is at least 2 inches and no more than 4 inches deep, and the vent system is designed so no trap sees more than 1 inch of water column pressure difference.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 1005.1, Trap seal depth: 2 to 4 inches; CPC 901.3, Trap seal pressure limit: 1 inch of water column.

Type B gas vent

A vent type for gas appliances such as a water heater. It ends at least 5 feet above the draft hood or flue collar, and its height above the roof depends on its size and distance from a wall.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 509.6, Gas vent (Type B) termination above the roof.

U

Underground inspection

The first of the three plumbing inspections. It happens after the trench is dug and bedded and the pipe is in, before any backfill goes on.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 105.2, Required inspections: underground, rough-in, final.

V

Vacuum relief valve

A device that stops a hot water tank from pulling a damaging vacuum. A storage tank or indirect water heater set higher than the fixture outlets in the hot water system needs one.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 608.7, Vacuum relief valve on a tank above the fixtures.

Vent (plumbing vent)

Pipe that gives air a path in and out of the drainage system so water drains smoothly and trap seals aren't siphoned or pushed out. Every fixture trap needs one under the code.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 901.2, Every fixture trap needs a vent; CPC 1002.1, Every trap needs a vent.

Vent stack

A vertical vent pipe whose job is moving air to and from the drainage system. Other vents tie into it, and a yoke vent connects it to the drainage stack.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 907.2, Yoke vent: 42 inches above the floor.

W

Water hammer arrester

A device that absorbs the shock when a quick-acting valve shuts hard. The code names the standards it has to meet and says to install it as close as possible to the quick-acting valves. The 2025 CPC marks this section as not adopted by HCD, the state housing agency, so ask your building department how it applies.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 609.11, Water hammer arresters at quick-acting valves.

Wet vent

A vent pipe that also carries drain flow. In a vertical wet vent, one pipe serves as both drain and vent for a few fixtures on the same story. In a horizontal one, a bathroom group shares a pipe sized for the load.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 908.1, Vertical wet venting: up to four fixtures, 6 feet; CPC 908.2, Horizontal wet vent for a bathroom group.

Wye

A Y-shaped drain fitting that joins a branch at an angle so waste keeps moving. The 45 degree wye and the combination wye and eighth bend are the standard fittings for joining drains.

Not a Chapter 2 term; the rule is in the library. In the code library: CPC 706.2, Horizontal drain entering a vertical stack; CPC 706.3, Horizontal drain joining another horizontal drain; CPC 706.4, Vertical drain turning into a horizontal drain.

Y

Yoke vent

A pipe that connects a vent stack to a drainage stack to balance pressure changes. It connects to the vent stack at least 42 inches above the floor.

Defined in CPC Chapter 2 (202.0). In the code library: CPC 907.2, Yoke vent: 42 inches above the floor.