CPC 402.10 · Fixtures

Access to concealed slip joints

Concealed slip joint connections need an access panel or utility space at least 12 inches in its least dimension, arranged without obstructions so the joints can be inspected and repaired.

2025 California Plumbing Code, Chapter 4 (Plumbing Fixtures and Fixture Fittings) · Applies to: Homes and commercial buildings

Front view of a wall behind a lavatory with an access opening at least 12 inches in its least dimension exposing the trap's slip joints.
A concealed slip joint needs an unobstructed access panel or utility space at least 12 in in its least dimension. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Slip joints are the compression-nut connections on a trap, tailpiece or tubular waste. When those connections end up hidden inside a wall, behind a tub or in a chase, the code wants a way to get to them.

The access panel or utility space has to be not less than 12 inches in its least dimension, and it has to be arranged without obstructions so the connections can be inspected and repaired. A panel with a stud or pipe running across the opening doesn't give you that access.

A trap in an open cabinet you can reach into is already accessible. The panel rule is for joints that get closed in.

On the job

  • Tub traps are the usual case. If the slip joints end up behind a wall or ceiling, plan an access panel or utility space on the back or side of the tub and make it the full 12 inches.
  • Decide where the panel goes before the wall is closed, and tell the framer and the finish carpenter. Cutting an opening after drywall and tile are up is the expensive way to fix a correction notice.
  • The inspector will look for the panel at final and for a clear path behind it: no blocking, pipe or wire across the opening.

The inspector and your city's adopted edition have the final word.