Shutoff valves inside each dwelling unit

In multidwelling buildings, each dwelling unit needs one or more accessible shutoff valves so one unit's fixtures can be shut off without stopping water to other units. Valves that control two or more openings have to be fullway gate or ball valves, or other approved types.

2025 California Plumbing Code, Chapter 6 (Water Supply and Distribution) · Applies to: Commercial buildings

A building riser feeding three dwelling units, each with its own accessible shutoff valve inside the unit.
Each unit gets accessible shutoff valves so one unit can be shut off without stopping the others. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

In a multidwelling building, each dwelling unit has to have shutoff valves arranged so the water supply to a fixture or a group of fixtures in that unit can be shut off without stopping the water to the other units.

These valves have to be accessible inside the dwelling unit they control, not out in a corridor chase the tenant can't reach.

Valves that control two or more openings have to be fullway gate valves, ball valves, or other approved valves designed for the service (606.4).

On the job

  • Locate the unit shutoff in a spot the occupant can reach, such as a utility closet or under a sink, and show it on the plans so framing leaves room for the access panel.
  • On a condo or apartment job, coordinate the valve locations with the general contractor before drywall so the access doors land in the right place.
  • Use full-port ball or gate valves for any valve controlling two or more openings.

The inspector and your city's adopted edition have the final word.