The rule
A control valve goes immediately ahead of each water-supplied appliance and immediately ahead of each slip joint or appliance supply.
In parallel water distribution systems, the control valve is either immediately ahead of each fixture or at the manifold. Valves at the manifold have to be identified with the fixture they serve.
If the manifold is in an attic, a crawl space or somewhere else that isn't readily accessible, a separate shutoff valve is required immediately ahead of each individual fixture or appliance.
Field-built manifolds follow the code's rules for valves, pipe and fittings. Manufactured manifolds have to meet IAPMO IGC 109.
On the job
- Label every manifold port with the fixture it feeds. An unlabeled manifold fails the identification rule even if everything else is right.
- Putting the manifold in a closet or garage with an access door is the cleanest way to keep the shutoff at the manifold.
- If the manifold has to go in the attic or crawl, put a stop at every fixture and appliance too.
The inspector and your city's adopted edition have the final word.