The rule
Storm and sanitary piping don't share pipes. A leader or conductor can't double as a soil, waste, or vent pipe, and a soil, waste, or vent pipe can't serve as a leader or conductor.
Leaders installed along alleys, driveways, or anywhere else they can get damaged are protected with metal guards, recessed into the wall, or built from ferrous pipe.
The building's sanitary and storm drainage systems stay entirely separate. The one exception is where a combined sewer is used. The building storm drain then connects in the same horizontal plane through a single wye fitting to the combined building sewer, and that wye is at least 10 feet downstream from a soil stack.
On the job
- A plastic downspout at a driveway corner gets hit sooner or later. Guard it or use a pipe that's meant to take a bump.
- Don't tap a roof drain leader into a stack for a vent or a drain. It's a clear violation.
- On a combined sewer, set the wye in the same plane as the main and measure the 10 feet from the soil stack before you cut.
The inspector and your city's adopted edition have the final word.