Home › Code Library › CPC 611.4

CPC 611.4 · Water supply and distribution

Sizing residential water softeners

Table 611.4 sizes a residential softener by the connection: 3/4 inch for up to 2 bathroom groups and 1 inch for up to 4. Over 4 bathroom groups, the softener size is engineered for the installation. The unit drains through an air gap.

2025 California Plumbing Code, Chapter 6 (Water Supply and Distribution) · Applies to: Homes

Table 611.4 connection sizes by bathroom groups next to a softener on the water line with an air gap drain.
3/4 inch connection for up to 2 bathroom groups, 1 inch for up to 4, engineered over 4. Drain through an air gap. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

A residential water softener is sized by the connection to the house. Table 611.4 allows a 3/4 inch connection for up to 2 bathroom groups and a 1 inch connection for up to 4 bathroom groups. Over 4 bathroom groups, the size is engineered for the specific installation.

The table notes say a kitchen sink and dishwasher, a laundry sink and an automatic clothes washer can be added without bumping the size up, and for the 3/4 inch size an additional water closet and lavatory are permitted.

Drinking water treatment units, softeners included, have to meet the standards in Table 611.1, which for a residential point-of-entry softener is NSF/ANSI 44. The discharge from the unit enters the drainage system through an air gap (611.2). And because any softener adds pressure loss, the pressure drop is counted in the pipe sizing (610.2).

On the job

  • Count the bathroom groups first, then match the connection size to the table. Over four groups, get the softener sized by whoever is engineering the system.
  • Make the drain connection with an air gap, not a direct connection to the waste line.
  • Add the softener's pressure drop to the sizing calculation and don't reduce the inlet or outlet size below the house distribution piping if you don't have pressure drop data (610.2).

The inspector and your city's adopted edition have the final word.

Give us a call

Call (760) 912-9831