The rule
Where a vertical pipe drops into a horizontal one, the water has to be turned with a long, gentle path, not a sharp elbow. The listed fittings are 45 degree wyes, combination wye and eighth bends, or other approved fittings of equivalent sweep.
A 60 degree (1.05 rad) branch or offset is allowed, but only where it's installed in a true vertical position, plumb.
This applies at the bottom of every stack and wherever a drop from an upper level lands on a horizontal line, like a stack landing on the building drain.
On the job
- At the base of a stack, a long-turn fitting or a wye with an eighth bend gets the flow onto the building drain without a short-radius elbow.
- A 60 degree fitting is only allowed where the pipe is true vertical, so check that it's plumb before you glue it in.
- Look at where the cleanout goes before you set the fitting. A turn at the base of a stack counts toward the cleanout rules in Section 707.4.
The inspector and your city's adopted edition have the final word.