The rule
Gutter capacity depends on three things: how big the gutter is, how steep it runs, and how hard it rains. Table 1103.3 gives the maximum roof area in square feet for each gutter diameter, at slopes of 1/16, 1/8, 1/4, and 1/2 inch per foot, across rainfall rates from 2 to 6 inches per hour.
A steeper gutter moves water faster and carries more. The same 5 inch gutter handles 625 square feet at 1/16 inch per foot and 1,770 at 1/2 inch per foot at 4 inches per hour.
The table is for semi-circular gutters. The design storm for roof drainage is the 60 minute, 100 year storm in Section 1101.12.1 unless the authority having jurisdiction requires something else.
On the job
- Pitch matters as much as size. A gutter hung nearly level can carry a fraction of the table's number for a steeper one.
- Add downspouts at the spacing the area calls for. Size each gutter run for the roof area that drains to it.
- If a customer wants a different gutter profile, ask the inspector how they want its capacity shown.
The inspector and your city's adopted edition have the final word.