CPC 312.2 · General rules

Pipe installed without strain, never embedded in concrete

Pipe can't be installed under undue strain. You have to allow for expansion, contraction and building settlement, and no plumbing pipe may be directly embedded in concrete or masonry.

2025 California Plumbing Code, Chapter 3 (General Regulations) · Applies to: Homes and commercial buildings

Two slab cross-sections: a pipe poured directly into concrete marked not allowed, and a pipe passing through a sleeve in a slab marked allowed, plus a hot line with an expansion offset.
Sleeve it, don't pour it: pipe passes through concrete in a sleeve, and runs have room to expand, contract and settle. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Two ideas share this section. First, pipe and its connections can't be forced into place or locked rigid where movement will bend, stretch or break them. The code expects you to make provisions for expansion, contraction and the structural settling every building does.

Second, plumbing pipe doesn't get cast directly into concrete or masonry. Where a pipe has to pass through a slab or a masonry wall, it goes through a sleeve or an opening (see 312.10), so it can move and be replaced without breaking concrete.

The last sentence covers framing. No structural member can be seriously weakened by cutting or notching. California says what counts by pointing to the California Building Code or California Residential Code, so the actual notching and boring limits live there.

On the job

  • Before a pour, check that every penetration has its sleeve or block-out, and that pipe isn't strapped or tied in a way that will pin it in the concrete.
  • Long rigid runs, hot water especially, need offsets, loops or hangers that let the pipe grow and shrink. Pipe clamped tight at both ends is a common cause of ticking and stress at fittings.
  • Inspectors look at pipe where it enters a slab or block wall. Pipe that goes straight into the concrete with no sleeve or wrap is a correction.

The inspector and your city's adopted edition have the final word.