CPC 312.3 · General rules

Drain pipe under or near a building: material and depth

Building sewer or drain pipe that isn't approved for use under or within a building can't go under a building or structure, within 2 feet of one, or less than 1 foot below the ground surface.

2025 California Plumbing Code, Chapter 3 (General Regulations) · Applies to: Homes and commercial buildings

Side view of a building and the ground beside it with the area under the building, the 2 foot strip beside it and the top 1 foot of soil shaded as off limits to pipe not approved for use under or within a building.
Pipe not approved for use under or within a building stays out of the shaded zone: under the structure, within 2 feet of it, and the top 1 foot of soil. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Read it as a material rule. Drain and sewer pipe that's approved for use under or within a building can go there. Pipe that isn't approved for that use stays out of three places: under the building or structure, within 2 feet of it, and shallower than 1 foot below the surface of the ground.

So the question isn't only depth. It's what the pipe is approved for. Whether a given material is approved for use under or within a building comes from the materials rules in the code and the approval process in Section 301.2, and the inspector has the last word.

Picture a zone: the footprint of the building, a strip 2 feet wide around it, and the top foot of soil. Pipe that's only approved for outdoor use stays out of that zone, or gets swapped for a material that's approved inside it.

On the job

  • Check the listing and markings on the pipe before it goes in a trench near the foundation. Pipe that's fine in the yard can be a correction at the building line.
  • Measure from the building or structure, and ask the inspector what the city counts as a structure when a patio, wall or addition is close.
  • Where a yard line has to come up shallow, check the cover before you backfill. As the code reads, less than 1 foot below the surface is for pipe that's approved for that use.

The inspector and your city's adopted edition have the final word.