Home › Code Library › CPC 402.5

CPC 402.5 · Fixtures

Toilet, bidet and urinal clearances

Set a water closet or bidet at least 15 inches from its center to a side wall or obstruction and at least 30 inches center to center from a similar fixture. Leave at least 24 inches of clear space in front of a water closet, lavatory or bidet. Urinals need 12 inches to the side wall and 24 inches center to center.

2025 California Plumbing Code, Chapter 4 (Plumbing Fixtures and Fixture Fittings) · Applies to: Homes and commercial buildings

Plan view of two water closets and two urinals with the 15 inch, 30 inch, 12 inch and 24 inch minimum clearances dimensioned from their centerlines, plus the 24 inch clear space in front.
Water closets: 15 in to the side wall, 30 in center to center, 24 in clear in front. Urinals: 12 in and 24 in. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Fixtures have to be set level and in proper alignment with the walls next to them. The side distances are measured from the center of the fixture, not from the edge of the bowl.

For water closets and bidets, the minimum is 15 inches from the center to a side wall or obstruction, and 30 inches center to center between similar fixtures. In front of a water closet, lavatory or bidet you need at least 24 inches of clear space. For urinals, the minimums are 12 inches from the center to a side wall or partition and 24 inches center to center.

Paper dispensers and accessibility grab bars aren't counted as obstructions. Accessible toilet rooms have their own, larger clearances in the California Building Code accessibility chapters, so check the plans for those.

On the job

  • Measure from the center of the closet flange to the finished wall, after tile or board goes up. That's the dimension the inspector will check.
  • Vanities and tub aprons are the usual culprits. A cabinet that sits inside the 15 inch line is an obstruction, and it's far cheaper to move the flange at rough-in than to move the cabinet at final.
  • Mark the 24 inch front clearance on the floor plan for small powder rooms. Door swings and vanities are what squeeze it.

The inspector and your city's adopted edition have the final word.

Give us a call

Call (760) 912-9831