Home › Code Library › CPC 407.2

CPC 407.2 · Fixtures

Faucet flow limits: lavatory and metering faucets

Residential lavatory faucets are capped at 1.2 gpm at 60 psi and can't fall below 0.8 gpm at 20 psi. Public lavatory faucets, and lavatory faucets in common areas of residential buildings, are capped at 0.5 gpm at 60 psi. Metering faucets deliver no more than 0.2 gallons per cycle.

2025 California Plumbing Code, Chapter 4 (Plumbing Fixtures and Fixture Fittings) · Applies to: Homes and commercial buildings

Horizontal bars comparing the 1.2 gpm residential lavatory faucet limit with the 0.5 gpm public and common-area limits, a 0.8 gpm minimum marker, and a note on metering faucets.
Residential lavatory faucets 1.2 gpm max (0.8 gpm min), public and common-area lavatory faucets 0.5 gpm, metering faucets 0.2 gallons per cycle. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Section 407.2 sets the maximum flow for faucets by where they're installed. A public lavatory faucet can't exceed 0.5 gpm at 60 psi. A residential lavatory faucet can't exceed 1.2 gallons per minute at 60 psi.

Residential lavatory faucets also have a floor. The flow can't be less than 0.8 gallons per minute at 20 psi.

Lavatory faucets in common and public use areas of residential buildings, meaning outside the dwellings or sleeping units, are held to 0.5 gallons per minute at 60 psi. Metered faucets deliver a maximum of 0.2 gallons per metering cycle.

Section 401.3 adds that a lower flow rate under California's appliance efficiency law (Title 20) wins over these numbers.

On the job

  • In a multifamily building the same project can carry two limits: 1.2 gpm for lavatories inside the dwelling units and 0.5 gpm for the lavatory in a lobby, laundry room or other common area.
  • Check the flow marking on the faucet or its box before you buy. A decorative faucet without a marking can get flagged at final.
  • Don't swap in a higher-flow aerator to fix a weak stream. Look at the supply pressure, the stops and a clogged aerator screen instead.

The inspector and your city's adopted edition have the final word.

Give us a call

Call (760) 912-9831