The rule
Showerheads have a maximum flow rate of 1.8 gallons per minute at 80 psi, and body sprays have the same 1.8 gpm cap. A hand-held shower counts as a showerhead.
California ties these to CALGreen. Residential showerheads comply with Division 4.3 of CALGreen, and residential body sprays follow the showerhead requirements. Nonresidential showerheads have to be certified to the U.S. EPA WaterSense specification for showerheads under Division 5.3, and nonresidential body sprays follow the showerhead rules too.
When a shower is served by more than one showerhead, the combined flow of all showerheads and other shower outlets controlled by a single valve can't exceed 1.8 gallons per minute at 80 psi. The other way to comply is a shower designed so only one outlet can be in operation at a time.
On the job
- A rain head plus a hand shower plus body jets on one valve is the usual problem. Add up the rated flows and keep the total at or under 1.8 gpm, or use a diverter that runs one outlet at a time.
- Leave the flow restrictor in the showerhead. The code limit is measured at 80 psi, so check the rating on the head or its box.
- Check the combined rating before the tile goes up. Changing the valve or outlets later means opening the wall.
The inspector and your city's adopted edition have the final word.