The rule
Showers get a waste outlet and fixture tailpiece not less than 2 inches in diameter. Tailpieces are made from the materials listed in Section 701.2 for drainage piping.
Strainers serving shower drains comply with ASME A112.18.2/CSA B125.2. On a site-built receptor, the drain also has to be an approved flanged floor drain that makes a watertight joint at the floor (see 408.8).
This section sets the outlet and tailpiece only. Trap size and venting come from the drainage and vent chapters.
On the job
- Check the markings on the drain body and strainer before you set it. A strainer that isn't marked to the standard is a swap at inspection.
- Linear and trench drains still need a 2 inch waste outlet and tailpiece. The style of drain doesn't change the rule.
- Set the drain flange at the right height for the pan and the finished slope. See 408.6 and 408.8 for slope and lining.
The inspector and your city's adopted edition have the final word.