CPC 409.4 · Fixtures

120 degree limit on tub and whirlpool filler water

Hot water from a bathtub or whirlpool bathtub filler is limited to 120°F (49°C), either by a limiting device conforming to ASSE 1070 / ASME A112.1070 / CSA B125.70 or CSA B125.3, or by a water heater conforming to ASSE 1084.

2025 California Plumbing Code, Chapter 4 (Plumbing Fixtures and Fixture Fittings) · Applies to: Homes and commercial buildings

A bathtub with a filler and a limiting device on the hot supply, with the 120 degree F limit labeled, and two options for meeting the rule.
Tub and whirlpool fillers top out at 120°F (49°C), by a limiting device or an ASSE 1084 water heater. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

The hottest water a bathtub or whirlpool bathtub filler can discharge is 120°F (49°C). That's scald protection at the tub.

The code gives two ways to comply. One is a limiting device conforming to ASSE 1070 (ASME A112.1070/CSA B125.70) or CSA B125.3. The other is a water heater conforming to ASSE 1084.

Tub-shower combinations have their own valve rule in 408.4. This section is the one that covers a tub filler by itself, like a deck-mounted or freestanding tub filler.

On the job

  • Check the temperature at the tub spout after you set the device, not only at the heater. Run it long enough to see the peak.
  • Keep the device's model and marking with the job file for the inspector.
  • For a freestanding or deck-mounted tub filler, plan where the limiting device goes before the floor or deck is closed in. It needs to be reachable for adjustment.

The inspector and your city's adopted edition have the final word.