The rule
Garages collect gasoline fumes and other vapors that sit low. So in a residential garage, and in spaces that open into it and aren't part of the living space, all heating elements, switches, burners and burner-ignition devices have to be at least 18 inches above the floor.
The exception is a listed flammable vapor ignition resistant (FVIR) appliance. Check the label to see whether the heater carries that listing.
Separately, an appliance in a garage or other place where it could be hit has to be guarded: behind protective barriers, or elevated or located out of the normal path of vehicles.
If the heater is in a separate enclosed space that opens only to the outside of the garage, it can sit at floor level as long as the combustion air comes from outside the garage.
On the job
- Measure from the garage floor to the lowest ignition source or burner on the actual heater, not to the bottom of the tank. A stand is the usual way to get a non-FVIR heater up to 18 inches.
- Put the barrier or bollards where a bumper would meet them first, and don't box the heater in so tight that you lose clearances or access.
- On a changeout, check the label for the FVIR listing. If it has it, the 18 inch rule doesn't apply, but the vehicle protection still does.
The inspector and your city's adopted edition have the final word.