CPC 603.1 · Backflow and cross-connections

Cross-connection control: water-operated equipment and treatment chemicals

Cross-connection control follows this chapter. Water-operated equipment, or a water-treating chemical, that can pollute or contaminate the domestic supply isn't allowed unless it's protected by an approved backflow device or assembly.

2025 California Plumbing Code, Chapter 6 (Water Supply and Distribution) · Applies to: Homes and commercial buildings

A decision chart: does the equipment or treating chemical pollute or contaminate the domestic supply, and if so is an approved backflow device or assembly provided.
Equipment that can foul the supply is allowed only with an approved backflow device or assembly. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

This is the general section that opens the cross-connection chapter. It does two things: it requires cross-connection control to follow the rules in Section 603, and it says nobody may install water-operated equipment, or use a water-treating chemical, that's found to pollute or contaminate the domestic supply.

There's a built-in exception. The same equipment or mechanism is allowed when it's fitted with an approved backflow prevention device or assembly. So the question on a job isn't whether the equipment can be used, it's whether it's protected.

The specific cases (boilers, water-cooled equipment, aspirators, irrigation, beverage dispensers and the rest) are in 603.5. This section is the catch-all behind them.

On the job

  • Water softeners, chemical feeders, process equipment and anything that uses water to do work are the ones to question. Look for the manufacturer's required device in the install instructions.
  • Put the protection ahead of the equipment on the supply side, then leave room for access, testing and a drain if the device can discharge. Check with the inspector before you order if you're unsure which assembly they'll accept.
  • When the equipment ships with an integral backflow preventer, install it per its listing and the manufacturer's instructions.

The inspector and your city's adopted edition have the final word.