The rule
A quick-acting valve, such as a clothes washer or dishwasher solenoid, stops the flow in an instant. That stop slams the moving water and sends a pressure spike through the piping. The code requires water hammer arrester(s) to absorb those pressures.
Arresters have to be approved mechanical devices that comply with ASSE 1010 or PDI-WH 201, and they're installed as close as possible to the quick-acting valves they protect.
Where a listed mechanical device is used, follow the manufacturer's specifications for location and installation method.
On the job
- Put the arrester at the appliance valve, not at the other end of the branch. As close as possible is the rule.
- Check the arrester's listing and follow the maker's sizing and placement instructions for where it can go in the line.
- The air chamber is not what the code approves here: the device is an approved mechanical device. Don't count on a capped stub of pipe.
The inspector and your city's adopted edition have the final word.