Home › Code Library › CPC 905.1

CPC 905.1 · Vents

Vent grade: no sags, drip back to the drain

Vent and branch vent pipes can't have drops or sags. Each one runs level or is graded and connected so it drains back by gravity to the drain pipe it serves.

2025 California Plumbing Code, Chapter 9 (Vents) · Applies to: Homes and commercial buildings

Two vent runs from a drain pipe: one graded to drain back by gravity, marked allowed, and one with a sag holding water, marked not allowed.
A vent runs level or graded back to the drain it serves, never with a sag that holds water. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Moisture can collect in a vent. The code gives it somewhere to go: every vent is level or sloped so it drains back to the drain it serves.

A sag is the real problem. It can hold water and block the vent, so the vent can't do its job.

On a long horizontal vent, the grade is toward the connection to the drain, not toward the roof.

On the job

  • Hanger spacing matters on horizontal vents. A hanger skipped in an attic can leave the pipe sagging by the time the insulation goes in.
  • Use a level or a line before you close the ceiling. A vent that looks fine from one end can sag in the middle.
  • Vents that rise before they run horizontal should still slope back to the drain along the horizontal part.

The inspector and your city's adopted edition have the final word.