The rule
A trap holds a plug of water that blocks sewer gas. Water rushing down a drain can pull that plug out behind it (siphonage) or push it back out ahead of it (backpressure). A vent gives air a way in and out so the seal stays where it belongs.
The rule is broad. Every fixture trap is protected unless another part of the code says otherwise, and air has to move through the whole drainage system, not just near the fixture. The rest of Chapter 9 is the how: vent size, grade, where a vent connects, and where it ends at the roof.
A few setups get relief from the standard one-vent-per-trap layout, such as wet venting, circuit venting, island sink loops, and combination waste and vent systems. Each one has its own conditions in its own section, so don't borrow the shortcut without the conditions.
On the job
- At rough-in the inspector looks for a vent path from every trap. Plan the vent routing at framing, before the walls close, so the pipe has a clear way up.
- A remodel that adds a fixture usually needs a new vent, or a legal way to share one. Find out where the nearest vent is before you promise a fixture location.
- Slow, gurgling drains and sewer smell after other fixtures run are the usual signs of a missing or blocked vent.
The inspector and your city's adopted edition have the final word.