Home › Free Tools › Drain slope and fall calculator

Free plumbing tool

Drain slope and fall

Drains run at least 1/4 inch per foot. Enter the length of your run and this tool gives the total fall, then checks a measured drop against the code. A 40 foot run needs 10 inches of fall.

Run the numbers

Fill this in to check a run you have already shot with a level.

Worked example

A 4 inch building drain, 40 feet long, with nothing measured yet.

  1. Standard slope, Section 708.1: 1/4 inch per foot × 40 feet = 10 inches of fall.
  2. With Authority Having Jurisdiction approval, 1/8 inch per foot × 40 feet = 5 inches of fall.

Result: 40 feet at 1/4 inch per foot needs 10 inches of fall. With approval, 1/8 inch per foot would need 5 inches.

The same run, after a level shot shows 7 inches of drop over the 40 feet.

  1. Standard slope, Section 708.1: 1/4 inch per foot × 40 feet = 10 inches of fall.
  2. With Authority Having Jurisdiction approval, 1/8 inch per foot × 40 feet = 5 inches of fall.
  3. Your measured drop: 7 inches ÷ 40 feet = 0.175 inch per foot.
  4. 0.175 is flatter than 1/4 but at least 1/8 inch per foot, which is allowed only with approval first.

Result: Your 7 inch drop over 40 feet is under 1/4 inch per foot. It's allowed only with approval. For the standard slope you'd need 10 inches of fall.

What the code says

  • Building drains and other horizontal drainage piping run at a uniform slope of at least 1/4 inch per foot, or 2 percent, toward the point of disposal (Section 708.1).
  • Where that is impractical, building drain piping 4 inches or larger may go to 1/8 inch per foot, or 1 percent, but only when the Authority Having Jurisdiction approves it first (Section 708.1).
  • Building sewers also run at 1/4 inch per foot. With approval where 1/4 isn't practical, 4 through 6 inch pipe may go to 1/8 and 8 inch and larger may go to 1/16 inch per foot (Section 718.1).
  • Smaller horizontal branch piping has no flatter option in these sections, so the tool holds it to 1/4 inch per foot.

Sections covered: 708.1 (building drain and horizontal drainage piping) and 718.1 (building sewers). The tool works in inches per foot over one straight run. It doesn't size the pipe or check vents, and it can't say whether your inspector will approve a flatter slope.

Read the full sections in the library: CPC 708.1 and CPC 718.1.

Sources

The inspector and your city's adopted edition have the final word. This tool is a summary of the code, not the code itself.

More free tools

Give us a call

Call (760) 912-9831