Home › Free Tools › Water heater first-hour rating tool

Free plumbing tool

Water heater size by first-hour rating

The California Plumbing Code sizes a storage water heater by its first-hour rating, the gallons it can deliver in one hour, not by tank size. A 2-bath, 3-bedroom house needs a rating of at least 62 gallons.

Run the numbers

A half bath adds a half.
Fill this in to check a heater you are looking at.

Worked example

A 2-bath, 3-bedroom house, checking a heater whose Energy Guide label shows a first-hour rating of 66 gallons.

  1. 2 bathrooms falls in the "2 to 2.5 bathrooms" group of Table 501.1(2).
  2. In that group, 3 bedrooms calls for a first-hour rating of at least 62 gallons.
  3. Your heater's label says 66 gallons, which is at least 62. It meets the table.

Result: Minimum first-hour rating: 62 gallons. A heater rated 66 gallons meets the minimum.

A 1-bath, 2-bedroom unit.

  1. 1 bathrooms falls in the "1 to 1.5 bathrooms" group of Table 501.1(2).
  2. In that group, 2 bedrooms calls for a first-hour rating of at least 49 gallons.

Result: Minimum first-hour rating: 49 gallons.

What the code says

  • The minimum capacity for storage water heaters follows the first-hour rating listed in Table 501.1(2) (Section 501.1).
  • The table is organized by bathrooms (1 to 1.5, 2 to 2.5, and 3 to 3.5) and bedrooms. A heater that meets the number for your row meets the table.
  • The first-hour rating is found on the Energy Guide label.
  • A solar water heater has to be sized to meet the same first-hour rating.

Rows covered: all 11 rows of Table 501.1(2), from 1 to 1.5 bathrooms with 1 bedroom up to 3 to 3.5 bathrooms with 6 bedrooms. Homes outside those rows aren't in the table, so the tool says so instead of guessing.

Read the full sections in the library: CPC 501.1.

Sources

The inspector and your city's adopted edition have the final word. This tool is a summary of the code, not the code itself.

More free tools

Give us a call

Call (760) 912-9831