CPC 1208.6 · Fuel gas piping

Gas meter location and selection

A gas meter has to be selected for the maximum expected pressure and the permissible pressure drop, and it has to sit in a ventilated space that's readily accessible for examination, reading, replacement or maintenance.

2025 California Plumbing Code, Chapter 12 (Fuel Gas Piping) · Applies to: Homes and commercial buildings

An exterior wall with a gas meter in open ventilated space with a clear access zone, beside a blocked enclosure that is not allowed.
Ventilated and readily accessible for reading, replacement and maintenance. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

Two rules cover meters. First, the meter is chosen for the highest pressure it will see and for the pressure drop the system can tolerate. Second, it has to be located in a ventilated space where someone can get to it easily to read it, look at it, swap it out or service it.

That makes closets, enclosed cabinets without ventilation and spots blocked by a fence or planter bad meter locations. A meter that can't be reached or aired out is a correction at the inspection.

Where the Authority Having Jurisdiction or the serving gas supplier requires it, a drip goes at the meter outlet. It's set up as a trap, so condensate that collects shuts off the flow before it can run back into the meter (Section 1210.7).

The gas supplier usually has its own rules about where meters can go. Check with them before you rough in.

On the job

  • Talk to the gas supplier early. Meter location, clearances and set pressure get settled before framing, not after the stucco is up.
  • Plan for access as well as the wall space. A meter behind a fence gate or tight against a property line can fail the 'readily accessible' test.
  • Keep landscaping, stored items and gates off the meter. Whoever lives there inherits the access problem.
  • Pressure drop matters on long runs. Coordinate the meter selection with the sizing in Section 1208.3.

The inspector and your city's adopted edition have the final word.