Home › Code Library › CPC 503.2

CPC 503.2 · Water heaters

Final water heater inspection

The Authority Having Jurisdiction inspects the water heater after the permitted work is installed, and no appliance or any part of it can be covered or concealed until it has been inspected and approved.

2025 California Plumbing Code, Chapter 5 (Water Heaters) · Applies to: Homes and commercial buildings

A water heater with numbered inspection points for the straps, relief valve and discharge pipe, pan, combustion air, vent and clearances, and a side panel that says nothing may be covered until approved.
Straps, relief valve and discharge, pan, air, vent and clearances all stay visible until the inspector signs off. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

The final inspection happens after the work authorized by the permit is in place. The inspector does whatever checking they consider necessary to be sure the work was installed in line with the intent of the code. The code doesn't give a fixed checklist, so what gets looked at is the inspector's call.

Nothing is covered or concealed until the inspector has inspected and approved it. That applies to the appliance and to any part of it. The vent has its own earlier inspection under Section 503.1, before it's covered.

In practice the inspector walks the pieces that the rest of Chapter 5 and Chapter 6 spell out: the strapping, the relief valve and its discharge pipe, the pan where one is required, combustion air, the vent and the clearances.

On the job

  • Leave the heater, vent and valves visible and reachable until the inspection is signed. A box built around the vent or a ceiling closed over a pan drain is a correction notice waiting to happen.
  • Walk it yourself first: straps in place, T&P discharge pipe ending where it can be seen, pan drain visible, vent connected and sloped, gas and water connections checked for leaks.
  • Keep the manufacturer's instructions on site. The inspector measures your install against them as well as the code.

The inspector and your city's adopted edition have the final word.