Home › Code Library › CPC 504.1

CPC 504.1 · Water heaters

Water heaters in bedrooms and bathrooms

A water heater in a bedroom or bathroom has to be direct-vent, or a fuel-burning heater has to sit in a closet with a listed gasketed self-closing door, outdoor combustion air, and nothing else in it.

2025 California Plumbing Code, Chapter 5 (Water Heaters) · Applies to: Homes and commercial buildings

Two panels: a direct-vent water heater venting through the wall, and a fuel-burning water heater in a closet with a gasketed self-closing door, threshold, bottom seal and outdoor combustion air.
Direct-vent, or a sealed closet with a self-closing gasketed door and outdoor combustion air, for the water heater alone. Diagram: Hoffman & Sons Plumbing (hoffmanandsons.com), CC BY 4.0. Free to share with credit. PNG · SVG · All diagrams

The rule

There are two ways to put a water heater in a bedroom or bathroom. One is a direct-vent water heater, which takes combustion air from outdoors and vents outdoors in a sealed arrangement. The other is a fuel-burning heater in a closet that opens off the bedroom or bathroom.

That closet has to be tightly detailed. It needs a listed, gasketed door assembly with a listed self-closing device, installed with a threshold and a bottom door seal. The door has to swing easily and freely and close and latch every time it's opened, with no hold-open feature. The gasketing has to follow the door, frame or gasket maker's listing.

Combustion air for the closet comes from outdoors under Section 506.4, and the closet is for the exclusive use of the water heater. No storage, no furnace sharing the space.

On the job

  • Check the room type early. A heater that was fine in a hall closet isn't automatically fine when the closet opens into a bathroom or bedroom.
  • Look for a hook-and-eye or doorstop on a closet door. The self-closing device can't have a hold-open feature, and a door someone props open defeats the whole idea.
  • Section 504.1 is written for water heaters in general and the closet option is for fuel-burning ones. If you're putting an electric heater in a bedroom or bathroom, ask the inspector how your city reads it.

The inspector and your city's adopted edition have the final word.

Give us a call

Call (760) 912-9831